The XIAOPAI FZRN12/25-12D is an indoor 12 kV AC vacuum load break switch combined with current-limiting fuses for short-circuit protection. Key ratings: 12 kV rated voltage, 20 kA breaking current, 50 Hz, 3-pole, 10,000-operation mechanical life. It is used in ring main units and compact substations where load switching and fault interruption must be handled by one device.
Vacuum interrupter for arc extinction — no oil or SF6, minimal maintenance
Fuse-striker interlock: when a fuse blows, the striker pin trips the switch automatically
Three-phase, 12 kV, 50 Hz design for indoor switchgear
10,000-operation mechanical life
Compact 96 × 58 × 93 cm footprint for RMU and box-type substations
MOQ 1 set — suitable for both replacement orders and project supply
Load switching — the vacuum interrupter opens and closes rated load current; the arc is extinguished inside the vacuum bottle within the first current zero.
Fault interruption — short-circuit current above the switch rating is cleared by the current-limiting fuse, not the switch.
Interlock — when any fuse operates, its striker pin drives the trip mechanism and opens all three poles, preventing single-phase running.
Isolation — after opening, the switch provides a visible isolating gap for safe maintenance.
Need a device that clears faults repeatedly? See our vacuum circuit breaker range.
12 kV ring main units (RMU)
Box-type and compact substations
Transformer incoming protection
Industrial plant and mining distribution cabinets
Cable branch boxes and switching stations
Ambient temperature: not higher than +40 °C, not less than -15 °C
Altitude: not exceeding 1000 m
Relative humidity: daily average ≤ 95%, monthly average ≤ 90%
Earthquake intensity: not more than 10 degrees
No fire or explosion hazard, serious pollution, chemical corrosion, or intense vibration
Selling unit: single item
Single package size: 96 × 58 × 93 cm
MOQ: 1 set
Trade term: FOB Ningbo
What is an FZRN12/25-12D load break switch?
An indoor 12 kV AC switchgear device combining a vacuum load break switch with current-limiting fuses — the switch handles load current, the fuse clears short circuits.
How is a load break switch different from a vacuum circuit breaker?
A load break switch interrupts rated load current but relies on fuses for fault current; a vacuum circuit breaker interrupts both. See our vacuum circuit breaker range.
What is the breaking capacity of the FZRN12/25-12D?
20 kA at 12 kV, 50 Hz.
What is the mechanical life?
10,000 operations.
What is the MOQ?
1 set. Lead time is confirmed per order configuration — contact us for a quote.
Where is it used?
Ring main units, compact substations, transformer incoming protection, and industrial distribution cabinets at 12 kV.
Need a quote for the FZRN12/25-12D? Send us your voltage, rated current and quantity — we reply within 24 hours.